This site uses cookies to improve your experience. To help us insure we adhere to various privacy regulations, please select your country/region of residence. If you do not select a country, we will assume you are from the United States. Select your Cookie Settings or view our Privacy Policy and Terms of Use.
Cookie Settings
Cookies and similar technologies are used on this website for proper function of the website, for tracking performance analytics and for marketing purposes. We and some of our third-party providers may use cookie data for various purposes. Please review the cookie settings below and choose your preference.
Used for the proper function of the website
Used for monitoring website traffic and interactions
Cookie Settings
Cookies and similar technologies are used on this website for proper function of the website, for tracking performance analytics and for marketing purposes. We and some of our third-party providers may use cookie data for various purposes. Please review the cookie settings below and choose your preference.
Strictly Necessary: Used for the proper function of the website
Performance/Analytics: Used for monitoring website traffic and interactions
This packed symposium will explore design concepts, tools, and approaches for fire-safe buildings, and highlight the role of fire safety in sustainable design and education. The event will also present insight into external living walls, battery/energy storage systems, façade systems, photovoltaics, mass timber, and more.
WASHINGTON, DC – A research project progressing from the American Iron and Steel Institute’s (AISI) Small Project/Fellowship Program has received significant funding through the National Science Foundation (NSF) to advance performance-based fire design for cold-formed steel (CFS) structures. Thomas Gernay, Ph.D.,
Photo courtesy Intertek As building codes and standards evolve, the demand for airtight, environmentally friendly building enclosures increases among building owners, insurers, and design professionals. Air barriers are essential for maintaining the integrity and performance of building enclosures.
To help in this regard, keep reading as we explore some of the most effective strategies for adapting to new building codes in 2025. What to Expect from Building Codes in 2025 As can be expected, standards of excellence are only set to increase in the construction industry in 2025.
An upgraded electrical system supports your maintenance activities effectively. Weatherproof outlets mounted 48 inches from the floor protect connections from moisture and damage. Weatherproof outlets mounted 48 inches from the floor protect connections from moisture and damage.
By Amy Becker Photo courtesy Fenestration and Glazing Industry Alliance (FGIA) Specifiers and design professionals should always consider seismic performance attributes for buildings in areas that previously have experienced the damaging effects of earthquakes. Building codes are adopted with the intent to preserve life and safety.
The post Top 10 Construction Defects: Prevent These Costly Building Mistakes appeared first on UK Construction Blog. The most dangerous defects include structural issues (foundation cracks, wall collapses), water infiltration, electrical/plumbing failures and HVAC system problems, which often remain hidden for years.
By Lisa May Photo Robert Casey/courtesy Tubelite With commercial architectural trends favoring expansive glass , curtain wall use is growing in newly constructed buildings. In common usage, curtain wall refers to aluminum-framed systems carrying glass, panels, louvers, or occasionally, granite or marble.
Laminators Incorporated presents AdaptaClad™ RS, a new shop-fabricated rainscreen wallsystem designed to provide significant time and labor savings to fabricators and installers. Its built-in adaptability makes it possible to install over almost any building substrate. Along with the launch of their new system, Laminators Inc.
Voice of the Brand When hurricanes, tornados, extreme temperatures, snow and ice, or salty ocean air have the potential to impact a structure, it is critical to design a building envelope system that will protect the occupants from the elements and deliver a comfortable environment.
For example, improved performance may be desired in a mechanical system intake plenum that will be exposed to rain and snow that infiltrates the louver, or at some other unique interior application. Unfortunately, the use of exterior-grade waterproofing within interior space has fire- and life-safety code implications that require analysis.
The structure fulfils high requirements in terms of energy efficiency, protection against the environmental influences and noise, durability, low maintenance, moisture regulation and sustainability. The all-in-one system of compatible products with tested and approved individual components covers a wide range of subframe solutions.
SD Hollow concrete block masonry was first used as a building material around 1870, when wooden molds were developed to produce concrete block units from a relatively dry mixture of sand, cement, and water. In current construction, concrete masonry units (CMUs) are used as both structural and architectural building materials.
Because I was new I had no idea was this crucial element to the building life safety systems were. Through my investigation I discovered that firestopping can be a range of materials that are installed in joints within walls, ceilings and floors that have a fire rating to slow the spread of fire throughout a structure.
By Shannon Humbert, Legacy Building Solutions Rigid-frame fabric buildings offer a permanent solution for athletic facilities. For many entities, both public and private, the need for an athletics and recreation facility comes down to two options: A permanent brick and mortar building, or a lower-cost fabric bubble.
Curtain wallsystems are ever present in today’s commercial construction marketplace. The architectural design of curtain walls must be developed alongside increasing demand for high-performing, energy-efficient solutions. Jackson, AIA Photo courtesy Simpson Gumpertz & Heger Inc.
The goals of buildingfire safety and energy efficiency are compatible when industry stakeholders work together to make sure proper assemblies are designed, the correct materials are specified, and installers have the experience to combine the building design and materials properly in the field. Building code overview.
Eventually, California’s HSR system will link more than 800 miles of rail, by way of up to 24 stations. Eventually, California’s HSR system will link more than 800 miles of rail, by way of up to 24 stations. s historic rail station for use as the first component of the intermodal high-speed rail commuter station.
It features elements that maximize the safety, security, and efficiency of the travel process including 100 percent automated screening lanes, 100 percent facial recognition “e-gates” for international departure, an innovative landside terminal design, and 100 percent trackable RFID Independent Carrier System.
Fire-rated Glazing Supports Safer School Design 1 kcichowicz Mon, 06/17/2024 - 11:12 Fire-rated glazing supports safer school design and supports building plans that meet model building code requirements. These standards simulate how a material or system might perform when subjected to similar situations in application.
Sergio Sádaba, Principal Industrial Facilities Designers Lists HVAC Mechanical Systems For most industrial factories, it’s process over people. As a buildings-performance expert, I have decades of experience designing high-performance, sustainable, and energy-efficient systems for a variety of industrial clients.
and Steven Gaynor, MBA Photo courtesy Tenmat New York City recently became the first jurisdiction in the country to reject and rewrite major sections of the International Building Code’s ( IBC ’s) language around fireprotection in exterior facades. For decades, buildings have relied on intumescent materials for fire control.
AIM Acoustic & Insulation Manufacturing has supplied wall cavity barriers and open state cavity barriers (OSCBs), along with technical support, for a ‘path-breaking’, 900-room student accommodation development at the University of West England Bristol’s Frenchay Campus. AIM’s products were supplied through SIG Manchester.
Fire-Rated Systems in Light-Frame Wood Construction 1 kcichowicz Thu, 07/20/2023 - 09:38 Multifamily Housing Find guidance on designing and building some of the most cost-effective, code-compliant fire-rated construction systems.
is experiencing a “wood revival” contributing to the complexity of fire-retardant-treated wood (FRTW) specifications. The building and fire codes require FRTW to be impregnated with chemicals. Interior FRTW is used in weather-protected applications ( i.e. where the FRTW is not permanently exposed to the elements).
Aligned with Alexandrias Green Building Policy, ACHS Minnie Howard Campus is targeting Net-Zero Energy and LEED Gold Certification through the U.S. Green Building Council. Meeting Perkins Eastmans project selection criteria, Rockfon ceiling systems help optimize sound absorption, enhance daylighting and support indoor air quality.
By Brendan Van Gool The primary function of a wallsystem is to act as an environment separator. For the last 50 years, the components and design of cavity wallsystems have undergone a significant transformation in North America. Sealed-joint cladding systems are no longer the de facto standard.
By Chuck Knickerbocker Photo Simon Hurst Photography/courtesy Technical Glass Products (TGP) Glazing systems are significant in connecting interior spaces to the outdoors, making them a popular option for todays sleek and modern building facades. Consider aluminumthe historical framing material for curtain walls.
Over four decades ago, it was where I first discovered a technologically advanced glass capable of resisting fire, smoke and heat. Something that wired glass, the only fire rated glass available and in use in the United States, could not. But would it pass our more stringent fire testing? market was unaware of it.
Using Multifunctional, Fire-rated Glass to Support Safer School Design 1 kcichowicz Mon, 08/19/2024 - 06:35 A multilayered approach to safer school design may create design challenges. Multifunctional, fire-rated glass offers a solution. In these areas, it is crucial for a door or window to defend against fire.
By David Hohenstern Photo by Dean Riggott/courtesy Sto Corp A renovation can be triggered by a wide range of factors: water intrusion issues, delaminating exterior finishes, cold walls, and new fire and energy performance regulations. These elements collectively form a high-performance exterior wall assembly.
Advances in fire resistant glazing have enabled modern performance expectations to be applied to architecturally sensitive and listed buildings as a variety of Promat SYSTEMGLAS® projects demonstrate. The project required a large fire resistant screen complete with fire doors to compartmentalise two areas of the building.
Architects, glaziers and building owners no longer had to settle for unsafe wire glass or expensive, tinted filmed and laminated ceramics. One look at SuperClear 45-HS and SuperClear 45-HS-LI and you can see why these products disrupted (and continue to disrupt) the 45 minute fireprotective glazing market.
EIT, and Tom Jaleski, ICC Photos courtesy RDH Building Sciences As the design and construction industry shifts toward more eco-conscious buildingsystems, mass timber has become a prominent element in this new direction. 2 Fire suppression/protectionsystems are required for most facilities.
2 Buildings are responsible for approximately 42 percent of CO2 emissions, 15 percent of which is attributed to the embodied carbon of materials. trillion sf) of building floorspace by 2060—equivalent space of New York City added every month for 40 years—the time for the industry to act is now. Millions of properties across the U.S.
Architects, glaziers and building owners no longer had to settle for unsafe wire glass or expensive, tinted filmed and laminated ceramics. One look at SuperClear 45-HS and SuperClear 45-HS-LI and you can see why these products disrupted (and continue to disrupt) the 45 minute fireprotective glazing market.
The post Breathing New Life into Historic Buildings: The Art and Science of Restoration appeared first on UK Construction Blog. The goal is to protect the legacy of these important structures while upgrading their functionality for modern use. Historical renovation projects require a delicate balance of preservation and adaptation.
First responders such as fire, EMS and police depend on reliable two-way radio communication when lives and property are at risk. That’s not always an easy task in many buildings. In-building radio signals are often absorbed or blocked by structures that are larger, underground, or constructed of concrete or metal.
DC FireProtection Ltd., based at Wellingborough in Northamptonshire, works right across the country covering multiple sectors of the construction industry, installing active as well as passive fireprotectionsystems. DC FireProtection Ltd.,
AIM – Acoustic & Insulation Manufacturing Fire Stop Blocks are now backed by test evidence covering a wider range of applications. Tested to the principles of BS EN 1366-4:2021, AIMs Fire Stop Blocks also have IFC Certification Ltd third-party certification. Our Fire Stop Block range is comprehensive.
Structure fires have dropped significantly over the past 40 years, and one major contributor to this decline in fires and fire deaths has been the development of comprehensive fire safety measures. These include performance testing requirements of model building codes. The International Building Code.
Waterproofing, fireproofing, concrete admixtures and more combined to protect and preserve these important landmarks. The expectation of ‘complete dryness’ called for a waterproofing system with a long-standing successful track record in difficult and harsh conditions. Fire proofing. Fireprotection. read more. .
Elevate Commercial Roofing Systems, a premier manufacturer of roofing, wall and lining systems, is proud to announce the expansion of its PVC product lineup with the introduction of MAX PVC and fleece-backed MAX PVC XR roofing membranes. Green Building Council. Visit HolcimElevate.com to learn more.
We organize all of the trending information in your field so you don't have to. Join 79,000+ users and stay up to date on the latest articles your peers are reading.
You know about us, now we want to get to know you!
Let's personalize your content
Let's get even more personalized
We recognize your account from another site in our network, please click 'Send Email' below to continue with verifying your account and setting a password.
Let's personalize your content