Remove Communication Remove Fire Protection System Installation Remove Masonry
article thumbnail

A Primer on MasterFormat & Improving Construction Project Collaboration

Building Information Management

Standardizing the presentation of renovation, repair, maintenance, and new construction tasks and costs improves communication and collaboration among all parties, as well as helps to assure financial transparency/. Divisions are the top Level (Level 1) in the hierarchy of the classification system. Existing Masonry Information.

article thumbnail

A Primer on MasterFormat & Improving Construction Project Collaboration

Building Information Management

Standardizing the presentation of renovation, repair, maintenance, and new construction tasks and costs improves communication and collaboration among all parties, as well as helps to assure financial transparency. . Divisions are the top Level (Level 1) in the hierarchy of the classification system. Existing Masonry Information.

Insiders

Sign Up for our Newsletter

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

article thumbnail

NFPA 285 engineering judgments

Construction Specifier

Structure fires have dropped significantly over the past 40 years, and one major contributor to this decline in fires and fire deaths has been the development of comprehensive fire safety measures. It is these multiple layers of fire safety, not a single requirement, which result in safe construction.

article thumbnail

What Is Falsework | Types of Falsework |Causes of Falsework Failures

CivilJungle

Falsework may be required to support steel and timber frameworks and masonry arches as well as in situ and precast concrete construction. • Shorbrace System. Cup-Lock Supporting System. Shorbrace System. The shorbrace support system is used widely to support the bridge deck. This system possesses many merits.

article thumbnail

Facilities Maintenance Checklist and Procedures

Job Order Contracting

This standard is not intended to address all fall protection related equipment. All fall protection equipment is required by OSHA to be checked prior to each use. Consult the Material Safety Data Sheets (MSDS) for hazardous ingredients and proper personal protective equipment (PPE). Special Instructions: 1. Lubricants.

article thumbnail

Construction Abbreviations – A Decent List

Building Information Management

CMU: Concrete Masonry Unit. CMUP: Concrete Masonry Unit Painted. CP: Cathodic Protection, Clothes Pole, Cesspool. CTSC: Communications Systems Terminal Cabinet. EIFS: Exterior Insulation and Finish System. EW & C: Electric Wiring and Communication. FA: Fire Alarm, Fresh Air. CLR: Clear.

article thumbnail

Construction Abbreviations – A Decent List

Building Information Management

CMU: Concrete Masonry Unit. CMUP: Concrete Masonry Unit Painted. CP: Cathodic Protection, Clothes Pole, Cesspool. CTSC: Communications Systems Terminal Cabinet. EIFS: Exterior Insulation and Finish System. EW & C: Electric Wiring and Communication. FA: Fire Alarm, Fresh Air. CLR: Clear.